Restriction Enzymes BseYI

A restriction enzyme or restriction endonuclease is defined as a protein that recognizes a specific, short nucleotide sequence and cuts the DNA only at or near that site, known as restriction site or target sequence. The four most common types of restriction enzymes inclue: Type I (cleaves at sites remote from a recognition site), Type II (cleaves within or at short specific distances from a recognition site), Type III (cleave at sites a short distance from a recognition site), and Type IV (targets modified DNA- methylated, hydroxymethylated and glucosyl-hydroxymethylated DNA). The most common challenges with restriction digest include- 1. inactivation of enzyme, 2. incomplete or no digestion, and 3. unexpected cleavage. The enzyme should always be stored at -20C and multiple freeze-thaw cycles should be avoided in order to maintain optimal activity. Always use a control DNA digestion with the enzyme to ensure adequate activity (to avoid interference due to high glycerol in the enzyme). For complete digestion, make sure that the enzyme volume is 1/10th of the total reaction volume, optimal temperature is constantly maintained throughout the reaction, the total reaction time is appropriately calculated based on the amount of DNA to be digested, appropriate buffers should be used to ensure maximal enzymatic activity, and in case of a double digest, make sure that the two restriction sites are far enough so that the activity of one enzyme cannot interfere with activity of the other. Star activity (or off-target cleavage) and incomplete cleavage are potential challenges which may occur due to suboptimal enzymatic conditions or inappropriate enzyme storage. To avoid these, follow the recommended guidelines for storage and reactions, and always check for the efficacy of digestion along with purification of digested products on an agarose gel.

Start discussion

No discussions found

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Found 1 matching solution for this experiment

BseYI NEB#R0635

New England BioLabs

Protocol tips
Prior to the RFLP, the multiplex PCR product was separated into three tubes for the genotyping of CYP3A4*4, CYP3A4*18B and CYP3A4*22 using BsmAI (NEB® Inc, Massachusetts, USA), RsaI (NEB® Inc, Massachusetts, USA) and BseYI (NEB® Inc, Massachusetts, USA) restriction enzymes (RE), respectively. The first tube contained 2.0 U BsmAI, 1× CutSmart NEBuffer® (NEB® Inc, Massachusetts, USA), 0.3–0.4 μg of PCR products and 9.2 μL doubly distilled water followed by incubation at 55 °C for 60 min. (Alpha Innotech, USA). The second tube contained 4.0 U of RsaI, 1× CutSmart NEBuffer® (NEB® Inc, Massachusetts, USA), 0.3–0.4 μg fresh PCR products and 8.8 doubly distilled water, followed by incubation at 37 °C for 60 min. The third tube contained 6.0 U BseYI, 1× NEBuffer 3.1® (NEB® Inc, Massachusetts, USA), 0.3–0.4 μg fresh PCR template and 8.4 μL doubly distilled water; incubated at 37 °C for 60 min followed by an inactivation step at 80 °C for 20 min. The incubation for all RFLP samples was carried out using an Accublock Digital Dry Bath.
Can't find the product you've used to perform this experiment? It would be great if you can help us by Adding a product!

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms