Select Host / Primary antibody raised in


FACS CD14

- Found 986 results

Get tips on using CD14 Antibody PE-labelled to perform FACS CD14 - Mouse Human PE

Products IQ products CD14 Antibody PE-labelled

Get tips on using PerCP Mouse Anti-Human CD14 to perform Flow cytometry Anti-bodies Human - CD14

Products BD Biosciences PerCP Mouse Anti-Human CD14

Get tips on using CD14 Monoclonal Antibody (61D3), eBioscience™ to perform Flow cytometry Anti-bodies Human - CD14

Products eBioscience CD14 Monoclonal Antibody (61D3), eBioscience™

Get tips on using PE/Cyanine7 anti-human CD14 Antibody to perform Flow cytometry Anti-bodies Human - CD14

Products BioLegend PE/Cyanine7 anti-human CD14 Antibody

Get tips on using PE/Cyanine7 anti-mouse CD14 Antibody to perform Flow cytometry Anti-bodies Mouse - CD14

Products BioLegend PE/Cyanine7 anti-mouse CD14 Antibody

Get tips on using CD14 Antibody, Pacific Orange™ conjugate to perform Flowcytometry CD14 - Mouse / IgG2a Human Pacific Orange™

Products Thermo Fisher Scientific CD14 Antibody, Pacific Orange™ conjugate

Get tips on using CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD14

Products eBioscience CD14 Monoclonal Antibody (Sa2-8), APC, eBioscience™

Get tips on using CD14 Monoclonal Antibody (Sa2-8), FITC, eBioscience™ to perform Flow cytometry Anti-bodies Mouse - CD14

Products eBioscience CD14 Monoclonal Antibody (Sa2-8), FITC, eBioscience™

Cellular assays Cell Isolation CD14+ cells

Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Proteins Flow cytometry Anti-bodies Mouse CD14

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms