Flow cytometry is an immunophenotyping technique whereby sing cell suspensions are stained for either cell surface markers or intracellular proteins by fluorescently-labelled antibodies and analyzed with a flow cytometer, where fluorescently-labelled molecules are excited by the laser to emit light at varying wavelengths, which is then detected by the instrument. There are several key criteria which are required to be kept in mind while designing a flow experiment- 1. Antibody titration (optimal dilution of antibodies should be calculated in order to avoid over- or under- saturated signals for proper detection of surface and intracellular markers), 2. Precision (3 or more replicates of the sample should be used per experiment), 3. Specificity (proper isotype controls should be included in the experiment), 4. Day-to-day variability (experiments should be repeated 3 or more times to ensure consistency and avoid variability due to flow cytometer settings), 5. Antibody interaction (Fluorescence minus one or FMO should be used, which is the comparison of signals from panel minus one antibody vs. the full panel), and 6. Antibody stability (fluorescently-labelled antibodies should be stored at 4C).

Start discussion

No discussions found

Start your discussion

Share your thoughts or question with experts in your field

Start a discussion

Found 3 matching solutions for this experiment

Upstream tips
Cells (106) were harvested after trypsinization, washed twice (for cell surface markers expression) or fixed with ethanol (for Ki-67 staining) and suspended in 500 μl PBS 1X containing 0,5% bovine serum albumin.
Protocol tips
The different antibodies were incubated for 30 min and washed to remove the excess of antibodies.
Downstream tips
The cytometric analysis was carried out using a fluorescence-activated cell sorting (FACS) Aria-II flow cytometer (BD Bioscience). The Flow Jo software was used for data acquisition and analysis, respectively, using measurements from 10,000 cells in each experiment.
Downstream tips
Fluorescence-activated cell sorting BD, FACSAria II SORP, and FACSDiva 8.0.1 software were used. After sorting, cells were seeded in ultra-low adherent plates for tumorsphere formation assays and treated with SFN or control (0.9% NaCl) for 7–10 days.
Protocol tips
the cells were incubated with antibody for 30 min at room temperature.
Downstream tips
All stained cell suspensions were detected or sorted using an AccuriC6 cytometer (BD Biosciences) and analyzed by FlowJo 7.6.1.