TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG

PCR Multiplex PCR - Mammalian DNA

Experiment
PCR Multiplex PCR - Mammalian DNA
Product
TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG from Thermo Fisher Scientific
Manufacturer
Thermo Fisher Scientific

Protocol tips

Upstream tips
Amplicon size should be consistent for each target sequence and limited to approximately 65 - 100 bp.

Publication protocol

RNA isolation was performed with the NucleoSpin RNA II kit (Macherey‐Nagel), as described by the manufacturer. Using cDNAs of transfected HEK293 cells, we performed quantitative expression analysis with the 7900HT Fast Real‐Time PCR System (Applied Biosystems). The PCR amplification was performed with TaqMan gene expression assay Hs01026070_m1 for human TRPM4. For control, we studied expression of a cotransfected human CD8 gene with TaqMan gene expression assay Hs00233520_m1. For each sample, triplicate determinations were performed in a 96‐well optical plate using 80 ng of cDNA, 1 μL of 20× TaqMan Gene Expression Assay, 10 μL of 2× TaqMan Fast Universal PCR Master Mix No AmpErase UNG, and 5 μL of water in each 20 μL reaction. Plates were heated for 20 seconds at 95°C, and then 40 cycles of 1 second at 95°C and 20 seconds at 60°C were applied. Relative TRPM4 expression (ΔCt) was calculated by subtracting the signal threshold cycle (Ct) of the control (CD8) from the Ct value of TRPM4. Subsequently, ΔΔCt values were obtained for each mutant by subtracting the ΔCt of the TRPM4 WT from the ΔCt of each mutant. Results were then linearized by calculating 2−expΔΔCt.

Full paper   Login or join for free to view the full paper.

Reviews

TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG from Thermo Fisher Scientific has not yet been reviewed for this experiment

We'd love it if you would be the first to write a review!

Discussion

Discussion

4 years ago

Author: R. Verma India

Multiplex PCR and qPCR

I have been doing multiplex PCR and qPCR separately. Is there a way to combine them in a single reaction using Sybr Green?

Discussion

4 years ago

Author: Roland Lafontaine France

My multiplex PCR has decreased in sensitivity

Hello there! My multiplex PCR has decreased in sensitivity even though I have not changed any of the parameters. The materials are in good condition and the PCR machine is well calibrated. I have tested multiple samples but one of my targets has decreased in sensitivity.

Share your thoughts or question with experts in your field by adding a discussion!

Papers

Check out relevant papers found by Labettor's AI that are relevant for performing PCR Multiplex PCR - Mammalian DNA using TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG from Thermo Fisher Scientific.

View full paper   Login or join for free to view the full paper.

Manufacturer protocol

Download the product protocol from Thermo Fisher Scientific for TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG below.

Download PDF Download manufacturer protocol

Videos

Check out videos that might be relevant for performing PCR Multiplex PCR - Mammalian DNA using TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG from Thermo Fisher Scientific. Please note that these videos are representative and steps or experiment specific processes must be kept in mind to expect desired results.

We haven't found any additional videos for this experiment / product combination yet.

Outsource your experiment

Fill out your contact details and receive price quotes in your Inbox

  Outsource experiment
Become shareholder Discussions About us Contact Privacy Terms